CVE-2019-19282 — A vulnerability has been identified in OpenPCS 7 V8

A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions < V8.2 Upd12), SIMATIC BATCH V9.0 (All versions < V9.0 SP1

CVSS
7.5 HIGH
EPSS
0.55% (top 32.30%)
CWE
CWE-131
Published
2020-03-10T19:16:17.000Z
Last modified
2024-08-05T02:09:39.657Z
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C

01What is this vulnerability?

A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions < V8.2 Upd12), SIMATIC BATCH V9.0 (All versions < V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET…

02Affected products

VendorProductVersions
SiemensOpenPCS 7 V8.1All versions
SiemensOpenPCS 7 V8.2All versions
SiemensOpenPCS 7 V9.0All versions < V9.0 Upd3
SiemensSIMATIC BATCH V8.1All versions
SiemensSIMATIC BATCH V8.2All versions < V8.2 Upd12
SiemensSIMATIC BATCH V9.0All versions < V9.0 SP1 Upd5
SiemensSIMATIC NET PC Software V14All versions < V14 SP1 Update 14
SiemensSIMATIC NET PC Software V15All versions
SiemensSIMATIC NET PC Software V16All versions < V16 Update 1
SiemensSIMATIC PCS 7 V8.1All versions
SiemensSIMATIC PCS 7 V8.2All versions
SiemensSIMATIC PCS 7 V9.0All versions < V9.0 SP3
SiemensSIMATIC Route Control V8.1All versions
SiemensSIMATIC Route Control V8.2All versions
SiemensSIMATIC Route Control V9.0All versions < V9.0 Upd4
SiemensSIMATIC WinCC (TIA Portal) V13All versions < V13 SP2
SiemensSIMATIC WinCC (TIA Portal) V14All versions < V14 SP1 Update 10
SiemensSIMATIC WinCC (TIA Portal) V15.1All versions < V15.1 Update 5
SiemensSIMATIC WinCC (TIA Portal) V16All versions < V16 Update 1
SiemensSIMATIC WinCC V7.3All versions
SiemensSIMATIC WinCC V7.4All versions < V7.4 SP1 Update 14
SiemensSIMATIC WinCC V7.5All versions < V7.5 SP1 Update 1

03Active exploitation status

Not currently listed on the CISA Known Exploited Vulnerabilities (KEV) catalog. EPSS is the best forward-looking signal — see the EPSS row above.

04Recommended remediation

05Technical details

For the full vendor write-up, exploit chains, and reference implementations, see the references list in section 09.

06Detection signatures

Ask SARA in chat to draft a starting detection for this CVE in your stack of choice.

07Related CVEs

No directly-cited follow-up CVEs in the KB record for this advisory. The references list in section 09 carries the vendor cross-references.

08Timeline

09References

Want this in your SOAR or SIEM?
SARA's API returns EPSS, CVSS, KEV, and an analyst-grade summary in one call.
Read the API reference →