The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components d
The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser…
| Vendor | Product | Versions |
|---|---|---|
| Mobile Industrial Robots A | S / MiR100 | v2.8.1.1 and before |
Not currently listed on the CISA Known Exploited Vulnerabilities (KEV) catalog. EPSS is the best forward-looking signal — see the EPSS row above.
For the full vendor write-up, exploit chains, and reference implementations, see the references list in section 09.
Ask SARA in chat to draft a starting detection for this CVE in your stack of choice.
No directly-cited follow-up CVEs in the KB record for this advisory. The references list in section 09 carries the vendor cross-references.