Campbell Scientific dataloggers CR6, CR300, CR800, CR1000 and CR3000 may allow an attacker to download configuration files, which may contain sensitive information about the internal network. From factory defaults, the mentioned datalogges have HTTP and PakBus enabled. The device
Campbell Scientific dataloggers CR6, CR300, CR800, CR1000 and CR3000 may allow an attacker to download configuration files, which may contain sensitive information about the internal network. From factory defaults, the mentioned datalogges have HTTP and PakBus enabled. The devices, with the default configuration, allow this situation via the PakBus port. The exploitation of this vulnerability may…
| Vendor | Product | Versions |
|---|---|---|
| Campbell Scientific | CR6 | all version |
| Campbell Scientific | CR300 | all version |
| Campbell Scientific | CR800 | all version |
| Campbell Scientific | CR1000 | all version |
| Campbell Scientific | CR3000 | all version |
Not currently listed on the CISA Known Exploited Vulnerabilities (KEV) catalog. EPSS is the best forward-looking signal — see the EPSS row above.
For the full vendor write-up, exploit chains, and reference implementations, see the references list in section 09.
Ask SARA in chat to draft a starting detection for this CVE in your stack of choice.
No directly-cited follow-up CVEs in the KB record for this advisory. The references list in section 09 carries the vendor cross-references.